Tube Based Fire Suppression System
Tube Based Fire Suppression System

Tube Based Fire Suppression System

MOQ : 1 Unit

Tube Based Fire Suppression System Specification

  • Voltage
  • No voltage required (mechanical activation)
  • Fire Extinguisher Type
  • Clean Agent (Novec 1230/FM200) or ABC Powder
  • Fire Class
  • Class A, B, C
  • Technology
  • Pneumatic Tube-Based Detection & Suppression
  • Connectivity Type
  • Standalone (optionally with panel integration)
  • Control Type
  • Automatic
  • Energy Efficiency Rating
  • Not Applicable (fully mechanical device)
  • Coverage Area
  • Varies with installation layout, typically 1 cabinet or 2-3 m2 per system
  • Shape
  • Cylinder with Flexible Sensing Tube
  • Mounting Type
  • Wall Mount or Panel Mount
  • Features
  • Quick Response, No Power Needed, Fully Self-Actuated, Zero False Alarms, Maintenance Friendly
  • Coating Type
  • Corrosion Resistant Powder-Coated
  • Operating Pressure
  • 15-25 bar
  • Installation Type
  • Direct Cabinet/Enclosure Mounting (Wall or Panel)
  • Working Temperature
  • -10C to +60C
  • Application
  • Server Rooms, Control Panels, Electrical Cabinets, Data Centers, Industrial Equipment
  • Max Flow Rate
  • Suitable for rapid discharge, up to 2 kg/sec (agent dependent)
  • Capacity
  • 1 kg / 2 kg / 4 kg / 6 kg (agent options)
  • Diameter
  • 8 mm (tube diameter)
  • Pressure
  • 15-25 bar (factory charged)
  • Compliance Standards
  • IS 15683, NFPA 2001 (Compatible)
  • Refilling
  • Yes, Fully Refillable and Serviceable
  • Response Time
  • Immediate (on direct flame or high heat contact)
  • Discharge Mechanism
  • Direct release of agent through tube rupture or nozzle
  • Agent Release Method
  • Local flooding or total flooding (depending on configuration)
  • Noise Level
  • Silent Operation
  • Detection Mechanism
  • Pressurized polymer tubing detects heat and bursts at fire location
  • Weight
  • System dependent, approx. 5-15 kg including agent and hardware
  • Material Construction
  • Seamless SS or Carbon Steel with powder coating
  • Safety Valve
  • Integrated Safety Relief Valve
  • Indicator
  • Visual Pressure Gauge on Cylinder
  • Expected Life Span
  • 5+ Years (with regular inspection)
  • Environment Impact
  • Eco-Friendly Agents (Novec 1230/ FM200)
  • Suitable Environments
  • Indoor, Dust-Prone, Electrical Sensitive Areas
 

Tube Based Fire Suppression System Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 50 Units Per Month
  • Delivery Time
  • 2-5 Days
  • Main Domestic Market
  • All India
 

About Tube Based Fire Suppression System



Introducing a magnificent deal: the New Tube Based Fire Suppression System, engineered for marvelously swift fire detection and suppression in ephemeral emergencies. Utilizing seamless SS or carbon steel with a corrosion-resistant powder coating, this gorgeous system features pressurized polymer tubing that bursts directly at fire locations, releasing eco-friendly agents (Novec 1230/FM200) for immediate response. Fully self-actuated and requiring no power, it operates silently and is maintenance-friendly. Compatible with IS 15683 and NFPA 2001, it's ideal for server rooms, panels, and dust-prone, electrical-sensitive environments-a truly marvelous safety solution, refillable and built to last over 5+ years.

Tailored Use and Distinct Features of Tube Based Fire Suppression Systems

Designed for flexible mounting inside server rooms, control panels, and industrial equipment, this system's application is especially effective in indoor, dust-rich, and electrically sensitive zones. With direct, automatic activation and zero false alarms, it guarantees immediate action upon fire detection. Notably, the system operates independently of electrical power and provides local or total flooding, matched to your needs. Its visual pressure gauge, integrated safety valve, and corrosion-resistant build underscore exceptional reliability and user-friendly maintenance.


Packaging, Delivery, and Sample Information for Peace of Mind

Each Tube Based Fire Suppression System is meticulously packaged using robust, secure materials ensuring safe transit. Once the asking price is confirmed and order is placed, your system is shipped swiftly with reliable logistics, typically dispatching within 7-10 business days across India. For customer confidence, sample policy options are available on request, ensuring the product aligns with your requirements prior to committing to bulk purchases. Enjoy a seamless transaction from inquiry to installation.


FAQ's of Tube Based Fire Suppression System:


Q: How does the tube-based fire suppression system detect a fire?

A: The system incorporates pressurized polymer tubing that senses high heat or direct flame. When exposed, the tube bursts at the nearest point of contact, instantly discharging the extinguishing agent to suppress the fire.

Q: What types of environments is this system best suited for?

A: It is ideal for indoor, dust-prone, and electrically sensitive areas such as server rooms, data centers, control panels, and industrial electrical cabinets.

Q: When does the system activate during a fire incident?

A: Activation is immediate-on direct contact with a flame or extreme heat, the pressurized tube ruptures and releases the agent, ensuring no delay in response.

Q: Where should the system be installed for best performance?

A: The system performs best when directly installed within cabinets, enclosures, or mounted in close proximity to sensitive equipment, maximizing its rapid response and coverage.

Q: What is the process for maintaining or refilling the fire suppression system?

A: The system is fully serviceable and refillable. Regular inspection is recommended to ensure performance, and refilling is easy; simply follow the manufacturer's guidelines or engage a professional service provider.

Q: What are the key benefits of using this tube-based solution over conventional systems?

A: This solution offers rapid, automatic detection and suppression with zero false alarms. It requires no external power, operates silently, and uses eco-friendly agents, making it maintenance-friendly and efficient for specific, localized applications.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Fighting System Category

Portable Fire Monitors

Portable Fire Monitors

Minimum Order Quantity : 1 Piece

Coverage Area : Wide area coverage, up to 45 meters throw

Application : FIRE FIGHTING

Working Temperature : 10C to 60C

Features : 360 horizontal rotation, vertical adjustment, corrosionresistant, lightweight, foam/water compatibility

Coating Type : Epoxy powdercoated

Adjustable Slide Valve Nozzle

Adjustable Slide Valve Nozzle

Minimum Order Quantity : 10 Pieces

Coverage Area : Variable Coverage depending on setting

Application : Fire Fighting Equipment

Working Temperature : Up to 60C

Features : Adjustable flow, brass body, corrosion resistant

Coating Type : Chrome Plated/Polished

Fire Suppression System

Fire Suppression System

Minimum Order Quantity : 10 Pieces

Coverage Area : Up to 150 m2

Application : Industrial, Commercial, Server Room, Electrical Panel

Working Temperature : 30C to +55C

Features : Low Residue, Fast Activation, Nonconductive, Environmentally Friendly

Coating Type : Epoxy Powder Coated

Nomex Industrial Suit

Nomex Industrial Suit

Minimum Order Quantity : 1 Piece

Coverage Area : Full body suit

Application : Fire Safety

Working Temperature : High heat resistant

Features : Reflective, Unisex

Coating Type : NOMEX Fabric



Back to top